CR-5 Firmware Manually Update

Manually Update the CR-5 Firmware Version

CR-5 手動更新韌體說明
Manually Update the CR-5 Firmware Version

 

適用:
Applicable to:

  1. 部分 CREST CR-5 錯誤寫入「CR5051 之工程版韌體」而致無法使用 DiveStory+ 更新為最新韌體,若您的手錶序號區間位於:
    CR5B21380191~CR5B21380325(黑色)
    或 CR5S21380111、CR5S21380187、CR5S21380196、CR5S21380210、CR5S21380243~CR5S21380246 (銀色)

    Few CREST CR-5 failed to update the latest firmware via app DiveStory+ due to write in the “Engineering version firmware CR5051” incorrectly. If the serial number of your watch is in the range of,
    CR5B21380191~CR5B21380325(Black)
    or CR5S21380111、CR5S21380187、CR5S21380196、CR5S21380210、CR5S21380243~CR5S21380246 (Silver)
  2. 少部分無線連線環境條件不相容以致無法使用DiveStory+成功更新韌體。
    A small number of wireless connections are incompatible with environmental conditions, causing firmware updates with DiveStory+ to fail.

 

請參照下方手動更新說明。
Please follow the updating instruction below.

 

-1-

請準備有 USB埠的 Windows電腦一台、CR-5、CR-5原廠充電器與CR-5原廠傳輸充電線,並將CR-5與電腦連接。

Please prepare a Windows PC with USB port, CR-5, CR-5 charger and CR-5 transfer/charging cable. Connect the CR-5 to the computer.

-2-

接上電腦後成功連線後,開啟「USB磁碟機」
即會看到 「SYSTEM」 資料夾。
此時接著再開 SYSTEM 資料夾內的 「EOPI」 資料夾。

After connecting to the computer and successfully connecting, open the “USB drive”
You will see the “SYSTEM” folder.
Then open the “EOPI” folder in the SYSTEM folder.

-3-

刪除 EOPI 資料夾內的檔案。

Delete the original files in the EOPI folder.

-4-

點選此連結並打開:https://bit.ly/3LCdcpM
下載連結資料夾裡的「BAK.bin」與「EOC05.bin」兩個檔案。

Click on this link and open:https://bit.ly/3LCdcpM
Download the “BAK.bin” and “EOC05.bin” files in the linked folder.

 

請逐一下載檔案並確認檔案格式為.bin檔。
或是直接下載資料夾,此時檔案為.zip壓縮檔,請解壓縮。
Please download the files one by one and make sure the file format is .bin file.
Unzip the .zip if it turned into .zip format, unzip is required.

-5-

回到手錶的「EOPI」資料夾,
將步驟4中下載的「BAK.bin」與「EOC05.bin」兩個檔案放進「EOPI」資料夾中。
兩個檔案存取完畢後,請正確的從電腦退出你的隨身碟(CR-5)。

Return to the “EOPI” folder of the watch.
Put the “BAK.bin” and “EOC05.bin” files which downloaded in step 4 into the “EOPI” folder.
Please eject the USB drive (CR-5) correctly from your computer after you finish accessing the two files.

-6-

成功退出並拔掉充電線後,CR-5 將會顯示「Update」,請耐心等待更新進度。
更新至100%進度後,請確認完成更新。

After successfully ejected and disconnected the charging cable, CR-5 will show “Update”, please wait patiently for the update progress.
After the update reaches 100% progress, please press the “OK” to confirm.

若無出現百分比%進度列而直接回到手錶模式則代表更新失敗,請回到步驟2重新操作一次
If the % progress bar does not appear and return to the watch mode, it means the update failed. Please go back to step 2 and try again.

-7-

確認更新後,請重置您的手錶才算完成韌體更新!
重置系統路徑:設定 > 重置 > 系統重置

After confirming the update, please reset your watch to complete the firmware update!
Reset system path: Settings > Reset > System Reset

-8-

至「關於」頁面查看手錶韌體版本是否成功
關於路徑:設定 > 關於

To check if the watch firmware version is updated successfully on “About” page.
About path: Settings > About

-1-

請準備有 USB埠的 Apple電腦一台、CR-5、CR-5原廠充電器與CR-5原廠傳輸充電線,並將CR-5與電腦連接。

Please prepare an Apple PC with USB port, CR-5, CR-5 charger and CR-5 transfer/charging cable. Connect the CR-5 to the computer.

-2-

接上電腦後成功連線後,開啟隨身碟資料夾「NO NAME」
即會看到 「SYSTEM」 資料夾。
此時接著再開 SYSTEM 資料夾內的 「EOPI」 資料夾。

After connecting to the computer and successfully connecting, open the USB folder “NO NAME”.
You will see the “SYSTEM” folder.
Then open the “EOPI” folder in the SYSTEM folder.

 

若找不到您的USB位置請參考: https://applealmond.com/posts/106134
If can not find your USB folder: https://www.macworld.co.uk/how-to/drive-not-showing-mac-3613422/
NO NAME > SYSTEM > EOPI

-3-

刪除 EOPI 資料夾內的檔案。

Delete the original files in the EOPI folder.

-4-

點選此連結並打開:https://bit.ly/3LCdcpM
下載連結資料夾裡的「BAK.bin」與「EOC05.bin」兩個檔案。

Click on this link and open:https://bit.ly/3LCdcpM
Download the “BAK.bin” and “EOC05.bin” files in the linked folder.

 

請逐一下載檔案並確認檔案格式為.bin檔。
或是直接下載資料夾,此時檔案為.zip壓縮檔,請解壓縮。
Please download the files one by one and make sure the file format is .bin file.
Unzip the .zip if it turned into .zip format, unzip is required.

-5-

回到手錶的「EOPI」資料夾,
將步驟4中下載的「BAK.bin」與「EOC05.bin」兩個檔案放進「EOPI」資料夾中。
兩個檔案存取完畢後,請正確的從電腦退出你的隨身碟(CR-5)。

Return to the “EOPI” folder of the watch.
Put the “BAK.bin” and “EOC05.bin” files which downloaded in step 4 into the “EOPI” folder.
Please eject the USB drive (CR-5) correctly from your computer after you finish accessing the two files.

-6-

成功退出並拔掉充電線後,CR-5 將會顯示「Update」,請耐心等待更新進度。
更新至100%進度後,請確認完成更新。

After successfully ejected and disconnected the charging cable, CR-5 will show “Update”, please wait patiently for the update progress.
After the update reaches 100% progress, please press the “OK” to confirm.

若無出現百分比%進度列而直接回到手錶模式則代表更新失敗,請回到步驟2重新操作一次
If the % progress bar does not appear and return to the watch mode, it means the update failed. Please go back to step 2 and try again.

-7-

確認更新後,請重置您的手錶才算完成韌體更新!
重置系統路徑:設定 > 重置 > 系統重置

After confirming the update, please reset your watch to complete the firmware update!
Reset system path: Settings > Reset > System Reset

-8-

至「關於」頁面查看手錶韌體版本是否更新成功
關於路徑:設定 > 關於

To check if the watch firmware version is updated successfully on “About” page.
About path: Settings > About

若您需要協助或無法成功手動更新,請聯繫您當地的代理商
If you need assistance or are still unable to update manually, please contact your local distributor.

代理商據點查詢 Find Your Distributer:
https://crestdiving.com/sales-locations/

若無法聯繫代理商請填寫右方表單,將由總公司替您服務
If you are unable to contact any sales agent, please fill out the form on the right, the head office will assist you.